{"product_id":"holzvergaserkessel-atmos-gs-20-20-kw","title":"Atmos GS 20 20 kW Wood Gasification Boiler","description":"\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eProduct Overview \u0026 Application\u003c\/h2\u003e\n\u003cp\u003eThe Atmos GS 20 wood gasification boiler is a manually fed hot water heating boiler for split logs, designed for heating single-family homes and similar properties. The unit operates on the wood gasification principle with an exhaust fan, which supports stable combustion and controlled heat output typical of this design. With a nominal output of 20 kW, this model is suitable for systems requiring a classic log boiler with clear, robust technology.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eTechnology \u0026 Features\u003c\/h2\u003e\n\u003cp\u003eThe boiler is designed for burning dry split logs. Combustion occurs using the downdraft gasification principle with an exhaust fan. The boiler body is made of steel sheets, and the secondary combustion chamber is equipped with ceramic components. Features include a boiler thermostat, flue gas thermostat, flow temperature thermometer, main switch, and mechanical operation of the start-up flap. A cooling loop is also included for protection against overheating.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eEveryday Advantages\u003c\/h2\u003e\n\u003cp\u003eIn practical operation, the Atmos GS 20 offers robust and straightforward boiler technology without unnecessary complexity. The large combustion chamber allows the use of split logs up to 330 mm in length. The wood gasification principle with preheated primary and secondary air supports even flame formation. Users will also appreciate the clear control layout, good accessibility for cleaning, and the electromechanical control system tailored to this boiler type.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eSystem Integration \u0026 Compatibility\u003c\/h2\u003e\n\u003cp\u003eThe Atmos GS 20 should be integrated into a professionally planned heating system with a buffer tank. The documentation explicitly recommends installation with a buffer tank and Laddomat 22 or a suitable return temperature boosting system to maintain the minimum return temperature and ensure clean operation. A minimum return temperature of 65 °C must be maintained for the boiler circuit, with the flow temperature set between 80 and 90 °C. For boiler outputs of 15 to 25 kW, pipe connections to buffer tanks should be made using 28x1 mm copper or 25 mm steel pipes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\n.product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd}\n\u003c\/style\u003e\n\u003cdiv class=\"product-th\"\u003e\n\u003ch2\u003eTechnical Specifications at a Glance\u003c\/h2\u003e\n\u003cp\u003eThe following technical data for the Atmos GS 20 is clearly documented in the available materials.\u003c\/p\u003e\n\u003ctable class=\"product-th__table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eNominal Output\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e20 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFuel\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eWood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eCombustion Technology\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eWood Gasification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e91.4 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eEnergy Efficiency Class\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eA+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. Flow Temperature\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e90 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. Operating Pressure\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e2.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eLog Length\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e330 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eBoiler Class\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eDraft Requirement\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e20 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFlue Gas Temperature\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e134.7 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFlue Pipe Connection\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e150\/152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eSafety Heat Exchanger\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eBuffer Tank Recommended\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eHeight\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eWidth\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e680 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eDepth\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e845 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFrequency\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e50 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eInstallation\u003c\/h2\u003e\n\u003cp\u003eInstallation must be carried out in accordance with applicable regulations and based on professional system planning. The boiler must be placed in a boiler room with an adequate supply of combustion air; for systems between 15 and 75 kW, the documentation specifies a combustion air opening of at least 350 cm². A foundation dimension of 700 x 600 mm is recommended for the GS 20. The connection to the chimney must be professionally executed, and the flue pipe connection should be as short as possible, rising, and no longer than 1 m.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eNotes\u003c\/h2\u003e\n\u003cp\u003eOnly dry split logs or chopped wood with a residual moisture content of 12 to 20 % should be used for operation. Fresh or overly damp wood impairs combustion and can negatively affect performance, consumption, and the lifespan of the boiler and chimney. When lighting the fire, set the flue gas thermostat to 0 °C; during operation, set it to the normal working range. According to the documentation, the boiler thermostat should be set to approximately 85 to 90 °C. Operation, connection, and electrical work must be carried out by qualified personnel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eScope of Delivery\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAtmos GS 20 Wood Gasification Boiler\u003c\/li\u003e\n\u003cli\u003eSteel Brush with Accessories\u003c\/li\u003e\n\u003cli\u003ePoker\u003c\/li\u003e\n\u003cli\u003eFill Valve\u003c\/li\u003e\n\u003cli\u003eOperating and Maintenance Manual\u003c\/li\u003e\n\u003cli\u003eHoneywell FR 124 Draft Regulator\u003c\/li\u003e\n\u003cli\u003eAsh Pan\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Atmos","offers":[{"title":"Default Title","offer_id":49423482552668,"sku":"01.05.20","price":23313.0,"currency_code":"RON","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/atmos-holzvergaser-gs20-effizienter-vergaserkessel-3014935.webp?v=1770692595","url":"https:\/\/ro.gemashop.de\/en\/products\/atmos-gs-20-20-kw-wood-gasification-boiler","provider":"GEMA Shop","version":"1.0","type":"link"}