{"product_id":"naturzugkessel-defro-firewood-plus-19-kw","title":"Natural Draft Boiler Defro Firewood Plus 19 kW","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026 Application\u003c\/h2\u003e \u003cp\u003eThe Defro Firewood Plus 19 kW natural draft boiler is a manually fed solid fuel boiler for split logs and use in central hot water heating systems. It is suitable for heating systems where a robust wood boiler with clear technical features, buffer tank connection, and professional integration into a closed heating system is intended.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026 Features\u003c\/h2\u003e \u003cp\u003eThe boiler body is constructed as a multi-pass steel structure with a water jacket. Combustion takes place via a cast iron grate with a steel insert in the combustion chamber, while primary air is supplied through the air flap and secondary air through side air inlets. The electronic draft regulator supports the control of the primary air flap, and an analog boiler thermometer is used for temperature monitoring on the unit.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThe arrangement of the loading door, ignition door, and ash door facilitates access to the combustion chamber, ash chamber, and cleaning areas. Turbulators in the convection channels support heat transfer within the boiler, while the insulation of the boiler body reduces heat loss. The integrated safety heat exchanger is an important component of the technical equipment for safe system operation.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026 Compatibility\u003c\/h2\u003e \u003cp\u003eThe Defro Firewood Plus 19 kW is intended for closed heating systems and must be combined with a buffer tank. Professional hydraulic integration, suitable return temperature boosting, and a properly designed flue gas system are required for operation. The design of the chimney, buffer tank, safety devices, and heating circuits should be coordinated within the overall system.\u003c\/p\u003e \u003c\/div\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical Data at a Glance\u003c\/h2\u003e \u003cp\u003eAn overview of the key technical data for the Defro Firewood Plus 19 kW.\u003c\/p\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eRated Output\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e19 kW\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFuel\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eSplit logs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eCombustion Technology\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eNatural draft\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eEfficiency\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e92.4 %\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eEnergy Efficiency Class\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eA+\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. Flow Temperature\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e90 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. Operating Pressure\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e3.0 bar\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. Log Length\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e340 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eBoiler Class\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e5 according to EN 303-5:2012\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eDraft Requirement\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e20 Pa\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFlue Gas Temperature\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e153 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFlue Pipe Connection\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eØ 159 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eSafety Heat Exchanger\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eBuffer Tank Recommended\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eRequired\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeight\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e1350 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eWidth\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e605 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eDepth\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e1035 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eWeight\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eapprox. 370 kg\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eVoltage\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e230 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFrequency\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e50 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFuse Rating\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e1.25 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePower Consumption\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003emax. 5 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePhases\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e1N\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eThe boiler should be set up and integrated in a suitable, ventilated, and frost-free boiler room. The hydraulic connection, electrical connection, and flue gas connection must be carried out professionally. A buffer tank, suitable return temperature boosting, and the integration of the required safety devices into the heating system must be provided for operation.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eOnly untreated split logs with an appropriate residual moisture content should be used for operation. The return temperature must be kept sufficiently high to protect the boiler body from harmful condensation and corrosion. Before installation, commissioning, and maintenance, the technical documents, requirements for heating water, chimney, and safety devices, as well as local regulations, must be observed.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of Delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eDefro Firewood Plus 19 kW natural draft boiler\u003c\/li\u003e \u003cli\u003eBoiler operating manual\u003c\/li\u003e \u003cli\u003eElectronic draft regulator\u003c\/li\u003e \u003cli\u003eAnalog boiler thermometer\u003c\/li\u003e \u003cli\u003eSteel insert for the combustion chamber\u003c\/li\u003e \u003cli\u003ePrimary air flap\u003c\/li\u003e \u003cli\u003eCleaning tool set\u003c\/li\u003e \u003cli\u003eCast iron grate\u003c\/li\u003e \u003cli\u003eTurbulator set\u003c\/li\u003e \u003cli\u003eSafety heat exchanger\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Defro","offers":[{"title":"Default Title","offer_id":49417957310812,"sku":"DFW19","price":14133.0,"currency_code":"RON","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/defro-firewood-plus-19-kw-heizkessel-effizientes-heizen-mit-scheitholz-6387175.webp?v=1770692688","url":"https:\/\/ro.gemashop.de\/en\/products\/defro-lemne-de-foc-plus-19-kw","provider":"GEMA Shop","version":"1.0","type":"link"}